Determination of optic nerve sheath diameter variability with age in pediatric groups and comparison of increased intracranial pressure and optic nerve sheath diameter in pediatric patients with head trauma

dc.contributor.authorYagar, Alper Burak
dc.contributor.authorKozaci, Nalan
dc.contributor.authorAvci, Mustafa
dc.contributor.authorYildiz, Sevim
dc.contributor.authorKaraman, Yasemin
dc.date.accessioned2022-02-22T11:25:28Z
dc.date.available2022-02-22T11:25:28Z
dc.date.issued2018
dc.departmentİnönü Üniversitesien_US
dc.description.abstractAim: The aim of this study is to reveal th evariability of the optic nerve sheath diameter (ONSD) with age and to compare the ONSD with increasing intracranial pressure (ICP) findings in computerised cranial tomography (CCT) images of pediatric patients presenting to the emergency department with head trauma. Material and Methods: The ONSD values of the patients were measured in the transverse sections of the CCT images. The patients who were found to have pathology in CCT images were taken into Group 1 and normal patients were taken in Group 2 as the control group. The data were recorded in the SPSS 21 program. The age, gender, Glasgow Coma Scale, and ONSD values of the groups and the difference between the ONSD values of both eyes were compared. Results: A total 294 patients were included in the study. Sixty eight patients (23%) were enrolled in Group 1 and 226 (77%) patients were enrolled in Group 2. The mean ONSD value of Group 1 was 5.5±1.08 mm whereas that of Group 2 was measured as 4.1±0.69 mm (p<0.001). One hundred sixty seven patients were discharged after 8-hour monitorization in the emergency room. These patients age were between 0 and 60 months. A statistically significant correlation was found between the ONSD values and ages of these patients (r:0.348, p=001). Conclusions: Simultaneous measurement of the ONSD and the ONSD difference is an effective method for determining the increase and severity of ICP in children with head trauma.en_US
dc.identifier.citationBurak Yagar, A., Kozaci, N., Avci, M., Yildiz, S., & Karaman, Y. (2021). Determination of optic nerve sheath diameter variability with age in pediatric groups and comparison of increased intracranial pressure and optic nerve sheath diameter in pediatric patients with head trauma . Annals of Medical Researchen_US
dc.identifier.urihttps://hdl.handle.net/11616/53800
dc.language.isoenen_US
dc.relation.ispartofAnnals of Medical Researchen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleDetermination of optic nerve sheath diameter variability with age in pediatric groups and comparison of increased intracranial pressure and optic nerve sheath diameter in pediatric patients with head traumaen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
460-465.pdf
Boyut:
349.67 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: