Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography
Yükleniyor...
Dosyalar
Tarih
2014
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Turkish Journal of Medical Sciences
Erişim Hakkı
info:eu-repo/semantics/openAccess
Özet
Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography Öz:
Abstract: Background/aim: To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. Materials and methods: Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL. Results: The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285). Conclusion: Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.
Abstract: Background/aim: To measure the positions of scleral-fixated intraocular lenses (IOLs) using anterior segment optical coherence tomography (OCT) and to evaluate the influence of the position of scleral-fixated IOL on the quality of vision. Materials and methods: Twenty-six eyes of 26 patients were included in the study. The average age was 57.5 (11 to 78) years. Anterior segment images were taken using slit lamp optical coherence tomography (SL-OCT) and were used to evaluate the position of the IOL. Results: The average amounts of tilt and decentration were 2.25° ± 1.93° and 359.28 ± 194.70 µm, respectively. There was a positive and moderate relationship between tilt and astigmatism caused by the position of the IOL (P = 0.030). No relationship was detected between decentration and the astigmatism caused by the position of the IOL (P = 0.285). Conclusion: Scleral-fixated IOL position can be evaluated with SL-OCT, which is a noncontact, noninvasive, reproducible, and reliable method of evaluation. Anterior segment OCT has been shown to provide sensitive measurements but not in all cases. The present study showed that a tilted scleral-fixated IOL behaved like a toric IOL, and the astigmatism caused by the position of the scleral-fixated IOL therefore could increase or decrease total astigmatism.
Açıklama
Yıl: 2014Cilt: 44Sayı: 6ISSN: 1300-0144 / 1303-6165Sayfa Aralığı: 1118 - 1123Metin Dili:İngilizce
Anahtar Kelimeler
Kaynak
Turkish Journal of Medical Sciences
WoS Q Değeri
Q4
Scopus Q Değeri
Cilt
44
Sayı
6
Künye
POLAT N,DEVRANOĞLU K. K,ÖZDAMAR M. A,ARICI C (2014). Evaluation of scleral-fixated intraocular lens position anomalies by anterior segment optical coherence tomography. Turkish Journal of Medical Sciences, 44(6), 1118 - 1123.