Effects of coating with different ceromers on the impact strength, transverse strength and elastic modulus of polymethyl methacrylate

dc.authoridGÜL AYGÜN, Esma Başak/0000-0002-9475-4035
dc.authoridGultek, Ahmet/0000-0002-4980-1568
dc.authoridESER, BEKIR/0000-0002-1280-1257
dc.authorwosidGÜL AYGÜN, Esma Başak/U-9647-2018
dc.authorwosidAsilturk, Meltem/B-2989-2013
dc.authorwosidGultek, Ahmet/AAG-5735-2019
dc.authorwosidESER, BEKIR/E-6250-2018
dc.contributor.authorGul, Esma Basak
dc.contributor.authorAtala, Mustafa Hayati
dc.contributor.authorEser, Bekir
dc.contributor.authorPolat, Nilufer Tulin
dc.contributor.authorAsilturk, Meltem
dc.contributor.authorGultek, Ahmet
dc.date.accessioned2024-08-04T20:40:17Z
dc.date.available2024-08-04T20:40:17Z
dc.date.issued2015
dc.departmentİnönü Üniversitesien_US
dc.description.abstractThe aim of this study was to evaluate the mechanical properties of polymethyl methacrylate (PMMA) after coating with different ceromers. For transverse strength and modulus of elasticity tests, specimens of 65x10x2.5 mm dimensions were prepared (5 groups, n=10). For impact strength test, specimens of 60x7.5x4 mm dimensions were prepared (5 groups, n=10). Test group specimens were coated with one of four different types of ceromers, and specimens in the control group were not coated. After specimens were tested for transverse and impact strengths, the data were analyzed with Kruskal-Wallis and Conover post hoc tests (p<0.05). GLYMOTEOS-TiO2 and A174-TEOS significantly increased the transverse strength of PMMA. All ceromers caused a statistically significant increase in the elastic modulus of PMMA. While GLYMO-TEOS-ZrO2 significantly decreased the impact strength, the other ceromers did not cause any statistically significant difference in impact strength. Coating with ceromers substantially improved the mechanical properties of PMMA.en_US
dc.description.sponsorshipInonu University Scientific Investigation Project, Malatya, Turkeyen_US
dc.description.sponsorshipThis study was supported by Inonu University Scientific Investigation Project, Malatya, Turkey.en_US
dc.identifier.doi10.4012/dmj.2014-203
dc.identifier.endpage387en_US
dc.identifier.issn0287-4547
dc.identifier.issue3en_US
dc.identifier.pmid25904101en_US
dc.identifier.scopus2-s2.0-84930513147en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage379en_US
dc.identifier.urihttps://doi.org/10.4012/dmj.2014-203
dc.identifier.urihttps://hdl.handle.net/11616/96812
dc.identifier.volume34en_US
dc.identifier.wosWOS:000358182600014en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherJapanese Soc Dental Materials Devicesen_US
dc.relation.ispartofDental Materials Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPMMAen_US
dc.subjectReinforcementen_US
dc.subjectCoatingen_US
dc.subjectCeromersen_US
dc.subjectMechanical propertiesen_US
dc.titleEffects of coating with different ceromers on the impact strength, transverse strength and elastic modulus of polymethyl methacrylateen_US
dc.typeArticleen_US

Dosyalar