Effects of the transcatheter closure of atrial septal defect on electrocardiographic and echocardiographic parameters six months after the closure

dc.contributor.authorAtaş, Halil
dc.contributor.authorCansel, Mehmet
dc.contributor.authorKurtoğlu, Ertuğrul
dc.contributor.authorPekdemir, Hasan
dc.contributor.authorÖzdemir, Ramazan
dc.date.accessioned2021-11-23T14:16:10Z
dc.date.available2021-11-23T14:16:10Z
dc.date.issued2017
dc.departmentİnönü Üniversitesien_US
dc.description.abstractAbstract: Although percutaneous transcatheter atrial septal defect (ASD) closure (TCC) has been performed on adults for a long time there is limited data about the effects of the procedure in the literature and the majority of studies have been performed on children. The study purposed to evaluate the impact of TCC on cardiac remodeling, electrical changes and exercise capacity in adults. Transthoracic echocardiography and electrocardiography were performed one day before and six months after TCC in 27 consecutive patients who underwent successful TCC. Twenty-seven age and sex matched healthy subjects were used as control group. Right ventricular (RV) diameter (had decreased from 44±6.3 to 34±3.9; p<0.001), right atrial (RA) diameter (had decreased from 38±5.6 to 34±4.7; p<0.001), systolic pulmonary artery pressure (sPAP) (had decreased from 38±5.1 to 32±4.3; p<0.001) and P dispersion (Pd) times (had decreased from 59±9.9 to 45.2±16.3; p<0.001) significantly decreased in patients with ASD after TCC. However, these parameters obtained after TCC were still higher compared with parameters of healthy controls. There were not significant differences regarding QT dispersion (QTd) times between ASD patients before and after TCC and healthy controls. New York Heart Association (NYHA) functional class of patients with ASD was significantly improved after TCC. The findings of the present study indicate that although TCC leads to significant improvements regarding right heart dimensions and sPAP and Pd values of ASD patients; residual deterioration still persists up to 6 months after the procedureen_US
dc.identifier.citationATAŞ H,CANSEL M,KURTOĞLU E,PEKDEMİR H,ÖZDEMİR R (2017). Effects of the transcatheter closure of atrial septal defect on electrocardiographic and echocardiographic parameters six months after the closure. Medicine Science, 6(2), 213 - 216.en_US
dc.identifier.endpage216en_US
dc.identifier.issn2147-0634
dc.identifier.issue2en_US
dc.identifier.startpage213en_US
dc.identifier.trdizinid263109en_US
dc.identifier.urihttps://hdl.handle.net/11616/43299
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/263109
dc.identifier.volume6en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.relation.ispartofMedicine Scienceen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEffects of the transcatheter closure of atrial septal defect on electrocardiographic and echocardiographic parameters six months after the closureen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
610e0982-7a64-49e2-8458-f8977c6727eb.pdf
Boyut:
227.74 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: