The effect of hemodialysis on hearing using pure-tone audiometry and distortion-product otoacoustic emissions
Küçük Resim Yok
Tarih
1998
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Karger
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Patients under treatment of hemodialysis (HD) frequently exhibit some degree of sensorineural hearing loss. Fifteen subjects and 10 controls were tested by using pure-tone audiometry (PTA) and distortion-product otoacoustic emissions (DPOAEs) before and after a HD treatment. Other parameters (blood pressure, body weight, blood chemistries) were also evaluated before and after HD: The purpose of this study was to determine the acute effect of HD on hearing level by measuring PTA and DPOAE before and after one HD session. The results from PTA and DPOAE testings showed that hearing was unaffected by HD. However, all 15 subjects revealed significantly poorer hearing, especially in the higher frequencies, compared to that of the controls (p < 0.0001). It was concluded then that HD is a safe treatment, and that the sensorineural hearing loss in these patients may be attributed to the preexisting renal disease.
Açıklama
Anahtar Kelimeler
distortion-product otoacoustic emissions, pure-tone audiometry, hearing loss, hemodialysis, end-stage renal disease
Kaynak
Orl-Journal For Oto-Rhino-Laryngology and Its Related Specialties
WoS Q Değeri
Q3
Scopus Q Değeri
Q2
Cilt
60
Sayı
6