Evaluation of monitorization in anesthesia applications outside the operating room, compatibility of standard infrastructure and equipment : A survey study

dc.contributor.authorDemiroz Aslan, Duygu
dc.contributor.authorFerlengez, Ayse Gul
dc.contributor.authorAltunkaya Yagci, Neslihan
dc.date.accessioned2022-12-16T10:44:34Z
dc.date.available2022-12-16T10:44:34Z
dc.date.issued2021
dc.departmentİnönü Üniversitesien_US
dc.description.abstractWe aimed to evaluate the suitability of monitoring, standard infrastructure and equipment in anesthesia applications of anesthesiology reanimation specialists and resident physicians working in Istanbul and increase the awareness of them. 106 anesthesiology reanimation specialists and resident physicians working in Istanbul and Malatya included in the study. The results of the survey consisted of 31 questions were obtained by collecting data via electronic data form on the web. Statistical analysis was used. In our study, the presence of oxygen supply, aspirator and probes in the areas of anesthesia outside the operating room, the presence of light source is sufficient, the most commonly used respiratory parameters of the monitoring methods and cardiovascular monitoring was followed. In these areas it was seen that 94% of the emergency trolleys were found and in the emergency boxes it was seen that the drugs used for cardiac arrhythmia and arrest treatment were usually found. There was a 40% defibrillator and a 60% support team for emergency situations and 56% of the system that could communicate for assistance. 74% of the recovery unit and 37% of the waste gas system were found outside the operating room. We believe that monitoring, compliance of standard infrastructure and equipment are effective to prevent complications in anesthesia outside the operating room applications.en_US
dc.identifier.citationASLAN D, FERLENGEZ A, YAGCÄ° N (2021). Evaluation of monitorization in anesthesia applications outside the operating room, compatibility of standard infrastructure and equipment : A survey study. Medicine Science, 10(4), 1216 - 1220. 10.5455/medscience.2021.04.143en_US
dc.identifier.doi10.5455/medscience.2021.04.143en_US
dc.identifier.endpage1220en_US
dc.identifier.issn2147-0634
dc.identifier.issue4en_US
dc.identifier.startpage1216en_US
dc.identifier.trdizinid504539en_US
dc.identifier.urihttps://doi.org/10.5455/medscience.2021.04.143
dc.identifier.urihttps://hdl.handle.net/11616/85812
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/504539
dc.identifier.volume10en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isoenen_US
dc.relation.ispartofMedicine Scienceen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleEvaluation of monitorization in anesthesia applications outside the operating room, compatibility of standard infrastructure and equipment : A survey studyen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
Ä°sim:
document - 2022-12-16T134423.415.pdf
Boyut:
400.17 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
Ä°sim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: