dc.description.abstractAim: To evaluate the accuracy and agreement of the measurements made with the Masimo Rad7 device in living donor hepatectomy (LDH). Materials and Methods: A total of 63 living liver donors (LLDs) with ASA I-II scores who scheduled for LDH were included in the study. The Masimo noninvasive measurement probe was inserted to measure SpHb (mg/dL), pleth variability index (PVI, %) and perfusion index (PI,%). Heart rate, mean artery pressure, SpO2, body temperature, BIS, PVI, SpHb, and PI were recorded as basal, after anesthesia induction, post-intubation, post-intubation plus 5 min, 10 min, and plus 1, 2, 3, 4, 5, 6 and 7h. In addition blood samples were collected for laboratory hemoglobin (Hblab) before the surgery incision and after the surgical procedure, and the values were recorded simultaneously with the other values. Results: Fifty-five LLDs age between 18 and 55 years were assessed. The mean PI value increased in all measurements compared to baseline, and it was statistically significant at the 5th minute (p<0.05). This value prominently decreased after the 20th minute and dropped below the baseline value at the 7th hour. This decrease was statistically significant at the 2nd hour measurements (p<0.05). A significant correlation was observed between SpHb and LabHb before the surgical incision (r=0.694, p<0.001). Correlation decreased in after surgery measurement. In addition, there was a statistically significant difference between the before surgery and after surgery PI measurements (p<0.001). Conclusion: We think that in LDH procedures, surgical process leads to a decrease in PI and reduces the accuracy of SpHb measurement, and thus, intraoperative SpHb monitoring should be evaluated together with PI value.en_US
dc.identifier.citationColak, Y. Z., & Aslan, D. D. (2021). Accuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during hepatectomy in living liver donors. Annals of Medical Researchen_US
dc.identifier.urihttps://hdl.handle.net/11616/55632
dc.language.isoenen_US
dc.relation.ispartofAnnals of Medical Researchen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleAccuracy of non-invasive hemoglobin monitoring by pulse CO-oximeter during hepatectomy in living liver donorsen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
Ä°sim:
2140-2144.pdf
Boyut:
255.74 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
Ä°sim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: