Preparation of pyridoxine-based polyurethane modified sensors and their use in simultaneous determination of Cu(II) - Co(II) ions
dc.authorid | Koytepe, Suleyman/0000-0002-4788-278X | |
dc.contributor.author | Savan, Ebru Kuyumcu | |
dc.contributor.author | Kazici, Dilek | |
dc.contributor.author | Ozcan, Imren | |
dc.contributor.author | Bayram, Songuel | |
dc.contributor.author | Koytepe, Sueleyman | |
dc.date.accessioned | 2024-08-04T20:56:12Z | |
dc.date.available | 2024-08-04T20:56:12Z | |
dc.date.issued | 2024 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description.abstract | In this study, pyridoxine-based polyurethane-modified electrodes were prepared to simultaneously and sensitively measure copper (Cu(II)) and cobalt (Co(II)) ions in complex matrix samples. For the production of the electrodes, firstly, the synthesis of pyridoxine-based polyurethane structures was carried out. In these syntheses, the polymer structure was diversified by using different isocyanates. Polyethyleneglycol-200 (PEG), pyridoxine (B6), and beta- cyclodextrin ( beta- CD) groups were used as the source of polyol. The synthesized polyurethane structures were characterized by different instrumental techniques and used in gold electrode surface modification. Modified sensor surfaces were examined by scanning electron microscopy and atomic force microscopy techniques. The prepared modified sensors were used for the simultaneous detection of Cu(II) and Co(II) ions using the differential pulse voltammetry technique. The limit of detection (LOD), limit of quantitation (LOQ), and R 2 values for Cu(II) ions were calculated as 8.81 mu M, 29.4 mu M, and 0.993, respectively. LOD, LOQ, and R 2 values for Co(II) ions were calculated as 9.84 mu M, 32.8 mu M, and 0.9935, respectively. For repeatability, the relative standard deviation (RSD %) of the prepared simultaneous sensors was determined as 1.54 and 1.71 for Cu(II) and Co(II), respectively. As a result, Cu(II) and Co(II) ions were measured independently and simultaneously with high sensitivity. According to these results, it is predicted that pyridoxine-based polyurethane-modified sensors may be suitable for the simultaneous detection of Cu(II) and Co(II) in medical, food, and agricultural samples. | en_US |
dc.description.sponsorship | The PCT application for this study and the designed sensor material were entered into the TURKPATENT records on 14/12/2023 with the application number PCT/TR2023/051546, and were transferred to the international stage. | en_US |
dc.identifier.doi | 10.1016/j.talanta.2024.126520 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.issn | 1873-3573 | |
dc.identifier.pmid | 39013339 | en_US |
dc.identifier.scopus | 2-s2.0-85198545614 | en_US |
dc.identifier.scopusquality | Q1 | en_US |
dc.identifier.uri | https://doi.org/10.1016/j.talanta.2024.126520 | |
dc.identifier.uri | https://hdl.handle.net/11616/102122 | |
dc.identifier.volume | 278 | en_US |
dc.identifier.wos | WOS:001271986700001 | en_US |
dc.identifier.wosquality | N/A | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.indekslendigikaynak | PubMed | en_US |
dc.language.iso | en | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Talanta | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cobalt sensor | en_US |
dc.subject | Copper sensor | en_US |
dc.subject | Pyridoxine | en_US |
dc.subject | Voltammetry | en_US |
dc.title | Preparation of pyridoxine-based polyurethane modified sensors and their use in simultaneous determination of Cu(II) - Co(II) ions | en_US |
dc.type | Article | en_US |