Preparation of pyridoxine-based polyurethane modified sensors and their use in simultaneous determination of Cu(II) - Co(II) ions

dc.authoridKoytepe, Suleyman/0000-0002-4788-278X
dc.contributor.authorSavan, Ebru Kuyumcu
dc.contributor.authorKazici, Dilek
dc.contributor.authorOzcan, Imren
dc.contributor.authorBayram, Songuel
dc.contributor.authorKoytepe, Sueleyman
dc.date.accessioned2024-08-04T20:56:12Z
dc.date.available2024-08-04T20:56:12Z
dc.date.issued2024
dc.departmentİnönü Üniversitesien_US
dc.description.abstractIn this study, pyridoxine-based polyurethane-modified electrodes were prepared to simultaneously and sensitively measure copper (Cu(II)) and cobalt (Co(II)) ions in complex matrix samples. For the production of the electrodes, firstly, the synthesis of pyridoxine-based polyurethane structures was carried out. In these syntheses, the polymer structure was diversified by using different isocyanates. Polyethyleneglycol-200 (PEG), pyridoxine (B6), and beta- cyclodextrin ( beta- CD) groups were used as the source of polyol. The synthesized polyurethane structures were characterized by different instrumental techniques and used in gold electrode surface modification. Modified sensor surfaces were examined by scanning electron microscopy and atomic force microscopy techniques. The prepared modified sensors were used for the simultaneous detection of Cu(II) and Co(II) ions using the differential pulse voltammetry technique. The limit of detection (LOD), limit of quantitation (LOQ), and R 2 values for Cu(II) ions were calculated as 8.81 mu M, 29.4 mu M, and 0.993, respectively. LOD, LOQ, and R 2 values for Co(II) ions were calculated as 9.84 mu M, 32.8 mu M, and 0.9935, respectively. For repeatability, the relative standard deviation (RSD %) of the prepared simultaneous sensors was determined as 1.54 and 1.71 for Cu(II) and Co(II), respectively. As a result, Cu(II) and Co(II) ions were measured independently and simultaneously with high sensitivity. According to these results, it is predicted that pyridoxine-based polyurethane-modified sensors may be suitable for the simultaneous detection of Cu(II) and Co(II) in medical, food, and agricultural samples.en_US
dc.description.sponsorshipThe PCT application for this study and the designed sensor material were entered into the TURKPATENT records on 14/12/2023 with the application number PCT/TR2023/051546, and were transferred to the international stage.en_US
dc.identifier.doi10.1016/j.talanta.2024.126520
dc.identifier.issn0039-9140
dc.identifier.issn1873-3573
dc.identifier.pmid39013339en_US
dc.identifier.scopus2-s2.0-85198545614en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.urihttps://doi.org/10.1016/j.talanta.2024.126520
dc.identifier.urihttps://hdl.handle.net/11616/102122
dc.identifier.volume278en_US
dc.identifier.wosWOS:001271986700001en_US
dc.identifier.wosqualityN/Aen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.relation.ispartofTalantaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCobalt sensoren_US
dc.subjectCopper sensoren_US
dc.subjectPyridoxineen_US
dc.subjectVoltammetryen_US
dc.titlePreparation of pyridoxine-based polyurethane modified sensors and their use in simultaneous determination of Cu(II) - Co(II) ionsen_US
dc.typeArticleen_US

Dosyalar