Dar aort annuluslu hastalarda yeni jenerasyon mekanik kapak: St. Jude regent aortik protez deneyimi

dc.contributor.authorErdil, Nevzat
dc.contributor.authorAteş, Şanser
dc.contributor.authorÇetin, Levent
dc.contributor.authorDemirkılıç, Ufuk
dc.contributor.authorŞener, Erol
dc.contributor.authorTatar, Harun
dc.date.accessioned2020-09-16T11:29:29Z
dc.date.available2020-09-16T11:29:29Z
dc.date.issued2001
dc.departmentİnönü Üniversitesien_US
dc.descriptionYıl: 2001Cilt: 9Sayı: 4ISSN: 1301-5680 / 2149-8156Sayfa Aralığı: 193 - 196Metin Dili:Türkçeen_US
dc.description.abstractÖz: Amaç: St. Jude Regent kalp kapak protezi daha iyi hemodinamik performans, daha az gradiyent ve artırılmış kapak alanına sahiptir. Bu çalışmada aortik pozisyonda St. Jude Regent kalp kapak protezi kullandığımız ilk 12 hastanın erken hemodinamik ve klinik sonuçlarını vermekteyiz. Materyal ve Metod: Eylül 2000 - Aralık 2000 tarihleri arasında kliniğimizde 12 hastada aortik pozisyonda St. Jude Regent protez kapak implante edildi. Ortalama yaş 55.2±12.4 olup hastaların 7'si erkekti. Yedi hastada izole aort kapak replasmanı (AVR), 4 hastada AVR + mitral kapak replasmam, 1 hastada AVR + koroner bypass ameliyatı gerçekleştirildi. Hastalar klinik durum ve ekokardiyografik olarak ortalama 5±2 aylık takip sonrası değerlendirildi. Bulgular: Olguların 8'sinde 21 mm, 4'ünde 19 mm ölçüsünde kapak takıldı. Tüm olgularda aort annulusu dardı ve kapakta darlık ön plandaydı. Perioperatif mortalite gözlenmedi. Ortalama kros klemp zamanı 49.1 ± 22.7 dak, ortalama kardiyopulmoner bypass zamanı 62.2 ± 23.8 dak, ortalama yoğun bakım kalış süresi 1 gün, ortalama postoperatif hastane kalış süresi 6.7 ± 0.7 gün idi. Hastaların hiçbirinde erken postoperatif ve takip döneminde komplikasyon saptanmadı. Postoperatif ekokardiyografik değerlendirmede efektif kapak alanı 19 mm kapak için 1.5 ± 0.4 cm2, 21 mm kapak için 1.9 ± 0.6 cm2, ortalama maksimum gradient 19 mm için 27 ± 8 mmHg, 21 mm için 18 ± 4 mmHg olarak tespit edildi. Takip periyodunda tüm hastaların fonksiyonel kapasiteleri klas I'de idi. Sonuç: St. Jude Regent mekanik kapak protezi düşük transvalvular gradiyent ve artırılmış kapak alanına sahip olması bakımından dar aort annuluslu hastalarda daha iyi hemodinamik fonksiyon sağlamaktadır.en_US
dc.description.abstractAbstract: Background: St. Jude Regent heart valve prosthesis has better hemodynamic performance, lesser gradient and increased effective orifice area. In this study, we present the early hemodynamic and clinical results of first 12 patients received St. Jude Regent heart valve prosthesis in aortic position. Methods: Between September 2000 - December 2000, St. Jude Regent heart valve prosthesis was replaced in aortic position in 12 patients. Mean age was 55.2 ± 12.4 years, and 7 of the patients were male. The procedures were isolated aortic valve replacement (AVR) in 7, AVR + mitral valve replacement in 4, and AVR + coronary artery bypass grafting in 1 patient. Patients were evaluated with echocardiography and also for clinical status in 5 ± 2 months of follow-up. Results: The valve size was 21 mm in 8, and 19 mm in 4 of the cases. In all patients the aortic annulus was small and valvular stenosis was the primary problem. There was no perioperative mortality. Mean cross clamp time was 49.1 ± 22.7 minutes, mean cardiopulmonary bypass time was 62.2 ±23.8 minutes, mean stay time in intensive care unit was 1 day, and mean hospital stay time was 6.7 ± 0.7 days. No complication was detected in the early postoperative period and during follow-up. In postoperative echocardiographic evaluation, effective orifice area was measured as 1.5 ±0.4 cm2 for 19 mm valve, and 1.9 ± 0.6 cm2 for 21 mm valve, also mean maximum gradient was measured as 27 ± 8 mmHg for 19 mm valve, and 18 ± 4 mmHg for 21 mm valve. All of the patients were in class I functional capacity during follow-up period. Conclusions: St. Jude Regent mechanical heart valve prosthesis provides better hemodynamic function due to lesser transvalvular gradient and increased effective orifice area in patients with small aortic annulus.en_US
dc.identifier.citationERDİL N,ATEŞ M. Ş,ÇETİN L,DEMİRKILIÇ U,ŞENER E,TATAR H (2001). Dar aort annuluslu hastalarda yeni jenerasyon mekanik kapak: St. Jude regent aortik protez deneyimi. Türk Göğüs Kalp Damar Cerrahisi Dergisi, 9(4), 193 - 196.en_US
dc.identifier.endpage196en_US
dc.identifier.issn1301-5680
dc.identifier.issn2149-8156
dc.identifier.issue4en_US
dc.identifier.startpage193en_US
dc.identifier.trdizinid15760en_US
dc.identifier.urihttps://hdl.handle.net/11616/18053
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/15760
dc.identifier.volume9en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.language.isotren_US
dc.publisherTürk Göğüs Kalp Damar Cerrahisi Dergisien_US
dc.relation.ispartofTürk Göğüs Kalp Damar Cerrahisi Dergisien_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.titleDar aort annuluslu hastalarda yeni jenerasyon mekanik kapak: St. Jude regent aortik protez deneyimien_US
dc.title.alternativeExperience of new generation mechanical valve in patients with small aortic annulus: St. Jude regent aortic prosthesisen_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
Makale Dosyası.pdf
Boyut:
66.21 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: