Exact time response computation of control systems with fractional order lag and lead compensators

dc.authorscopusid7202696962
dc.authorscopusid7201354300
dc.authorscopusid56448379000
dc.authorscopusid56108025700
dc.contributor.authorTan N.
dc.contributor.authorAtherton D.P.
dc.contributor.authorYuce A.
dc.contributor.authorDeniz F.N.
dc.date.accessioned2024-08-04T20:03:30Z
dc.date.available2024-08-04T20:03:30Z
dc.date.issued2016
dc.departmentİnönü Üniversitesien_US
dc.description.abstractIn this paper, two exact methods are developed for the computation of unit step and unit impulse responses of closed loop control systems with fractional order lag and lead compensators. The methods are based on using the frequency response data of the closed loop fractional order control system. It is shown that the unit step and unit impulse responses of a feedback control system including a fractional order lag or lead controller can be computed exactly using Fourier series of a square wave and inverse Fourier transform of frequency response information namely gain and phase values. Time response equations which are the function of controller parameters are derived. A design procedure is given for estimating the parameters of a fractional order lag or lead compensator which give specified performance values of the closed loop system. Numerical examples are provided to show the success of the presented method. © 2016, North Atlantic University Union. All rights reserved.en_US
dc.identifier.endpage268en_US
dc.identifier.issn1998-4464
dc.identifier.scopus2-s2.0-84968912309en_US
dc.identifier.scopusqualityN/Aen_US
dc.identifier.startpage260en_US
dc.identifier.urihttps://hdl.handle.net/11616/91866
dc.identifier.volume10en_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherNorth Atlantic University Unionen_US
dc.relation.ispartofInternational Journal of Circuits, Systems and Signal Processingen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFractional order control systemen_US
dc.subjectFractional order lag and lead compensatorsen_US
dc.subjectFrequency responseen_US
dc.subjectImpulse responseen_US
dc.subjectStep responseen_US
dc.subjectTime responseen_US
dc.subjectTime response from frequency responseen_US
dc.titleExact time response computation of control systems with fractional order lag and lead compensatorsen_US
dc.typeArticleen_US

Dosyalar