Assessment of atrial conduction time by tissue Doppler echocardiography and P-wave dispersion in patients with mitral annulus calcification

dc.authoridCansel, Mehmet/0000-0003-4740-4371
dc.authoridAkaycan, Jülide/0000-0002-9174-6777
dc.authoridPekdemir, Hasan/0000-0002-4913-5120
dc.authoridTaşolar, Hakan/0000-0002-1249-7240;
dc.authorwosidErmis, Necip/A-5184-2018
dc.authorwosidCansel, Mehmet/ABI-6324-2020
dc.authorwosidAkaycan, Jülide/ABI-2397-2020
dc.authorwosidPekdemir, Hasan/ABI-6096-2020
dc.authorwosidTaşolar, Hakan/ABG-4466-2020
dc.authorwosidErmis, Necip/HJP-7061-2023
dc.contributor.authorPekdemir, Hasan
dc.contributor.authorCansel, Mehmet
dc.contributor.authorYagmur, Julide
dc.contributor.authorAcikgoz, Nusret
dc.contributor.authorErmis, Necip
dc.contributor.authorKurtoglu, Ertugrul
dc.contributor.authorTasolar, Hakan
dc.date.accessioned2024-08-04T20:32:25Z
dc.date.available2024-08-04T20:32:25Z
dc.date.issued2010
dc.departmentİnönü Üniversitesien_US
dc.description.abstractThe aim of our study was to investigate atrial conduction time in patients with mitral annulus calcification (MAC) using P-wave dispersion (PWD) and electromechanical coupling measured with the surface electrocardiogram and the tissue Doppler echocardiography. Fifty-nine patients with MAC and 43 control subjects underwent resting the surface electrocardiogram and tissue Doppler echocardiography. The difference between the maximum (Pmax) and minimum P-wave durations was calculated and defined as PWD. Interatrial and intraatrial electromechanical delays were measured with tissue Doppler echocardiography. Both Pmax and PWD were higher in patients with MAC compared with controls (111.4 +/- 15.8 vs 97.3 +/- 18.8 milliseconds; P < .0001 and 46.4 +/- 14.6 vs 31.4 +/- 13.1 milliseconds; P < .0001, respectively). Both interatial and intraatrial conduction time were also delayed in patients with MAC compared with controls (29.8 +/- 13.3 vs 17.6 +/- 12.5 milliseconds; P < .0001; 9.4 +/- 5.1 vs 6.8 +/- 4.0 milliseconds; P < .008, respectively). Left atrial (LA) diameter was significantly higher in patients with MAC compared with controls (35.4 +/- 5.0 mm vs 32.3 +/- 4.2 mm; P < .001). The LA diameter correlated significantly with both interatrial conduction times and PWD (r = 0.56; P < .0001 and r = 0.47; P < .0001, respectively). There is a delay in both intraatrial and interatrial electromechanical coupling intervals in patients with MAC. (C) 2010 Elsevier Inc. All rights reserved.en_US
dc.identifier.doi10.1016/j.jelectrocard.2010.02.013
dc.identifier.endpage343en_US
dc.identifier.issn0022-0736
dc.identifier.issue4en_US
dc.identifier.pmid20381064en_US
dc.identifier.scopus2-s2.0-77953606264en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage339en_US
dc.identifier.urihttps://doi.org/10.1016/j.jelectrocard.2010.02.013
dc.identifier.urihttps://hdl.handle.net/11616/95061
dc.identifier.volume43en_US
dc.identifier.wosWOS:000279483000013en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherChurchill Livingstone Inc Medical Publishersen_US
dc.relation.ispartofJournal of Electrocardiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectMitral annulus calcificationen_US
dc.subjectP-wave dispersionen_US
dc.subjectAtrial electromechanical couplingen_US
dc.subjectTissue Doppler echocardiographyen_US
dc.titleAssessment of atrial conduction time by tissue Doppler echocardiography and P-wave dispersion in patients with mitral annulus calcificationen_US
dc.typeArticleen_US

Dosyalar