Kit bağımlı beckman synchron cx3 analizörü için alternatif kreatinin çözeltisi

dc.authoridTR6818en_US
dc.authoridTR107816en_US
dc.authoridTR7064en_US
dc.authoridTR5774en_US
dc.contributor.authorTemel, İsmail
dc.contributor.authorÇığlı, Ahmet
dc.contributor.authorTürköz, Yusuf
dc.contributor.authorÖzerol, Elif
dc.contributor.authorGözükara, Engin M.
dc.date.accessioned2015-11-02T10:15:58Z
dc.date.available2015-11-02T10:15:58Z
dc.date.issued1997
dc.departmentİnönü Üniversitesien_US
dc.description[Journal of Turgut Ozal Medical Center 1997;4(2):182-186]en_US
dc.description.abstractBeckman Synchron CX3 otoanalizörü kit bağımlı bir klinik analizördür. Kolay kullanımı, doğru ve kesin sonuçları ile 24 saat sürekli çalışma gibi avantajlarından dolayı laboratuvarımızda acil analizlerde kullanılmaktadır. Fakat cihazın kapalı sistem olması, çok fazla bakım ve aşırı miktarda reaktife ihtiyaç duyması gibi bazı önemli dezavantajları da vardır. Özellikle reaktif fiyatının yüksek olması nedeniyle alternatif reaktif aramak zorunda kaldık ve Synchron CX3 de kullandığımız bazı reaktifleri ürettik. Orijinal ve ürettiğimiz reaktiflerin lineeritesini kıyasladığımızda her ikisinin de aynı kullanılabilir lineer test aralıklarına sahip olduklarını gördük (serum: 0 ile 25 mg/dL ; idrar: 10 ile 40 mg/dL). Kontrol serumu kullanarak, sonuçların doğruluğunu araştırdık ve aralarındaki korelasyon katsayısının 0.999 a eşit olduğunu bulduk. Ayrıca farklı serum ve idrar örneklerinden elde edilen sonuçları lineer regresyon ile kıyasladık ve aralarındaki ilişkinin y = 0.98lx - 0.02 olduğunu saptadık Bunlara ilaveten her iki çözeltinin de hemolizden etkilenmediğini fakat yüksek miktarlarda lipemi ve bilirübin varlığından etkilendiklerini tespit ettik. Sonuç olarak laboratuvarımızda ürettiğimiz kreatinin reaktifı ile orijinal Beckman reaktifinin tamamen aynı özellikleri taşıdığını gördük, ancak ürettiğimiz reaktif orijinal reaktiften en az 10 kat daha ucuzdu.en_US
dc.description.abstractThe Beckman Synchron CX3 otoanalyzer is a reagent-dependent clinical analyzer. Because of its advantages such as easy usage, accurate and precise results and working continuously for 24 hours it is used in our laboratory for stat analysis. But the analyzer has also some important disadvantages. It has an unopened system, requires much more maintenance procedures and large reagent volum. Because of its too high reagent cost we were obligated to search an alternative reagent and have produced some reagents used on the Synchron CX3. When we compared linearity of the reagents, we observed that they had same usable lineer test ranges (serum: from 0 to 25 mg/dL ; urine: from 10 to 40 mg/dL). We searched accuracy of the results using same control serum and found correlation coefficient among them equals to 0.999. We also compared the results obtained from different serum and urine samples by linear regression, and found the relation between them as y = 0.981x - 0.02. In addition to these criteria, we determined that both of reagents were not affected from hemolysis but were affected from high degress of lipemia and bilirubinemia. ^s a result, we observed that creatinine reagent produced in our laboratory had completely same properties with original Beckman creatinine reagent, but our reagent was cheaper than original reagent at least 10 times.en_US
dc.identifier.citationTemel, İ.,Çığlı, A.,Türköz, Y.,Özerol, E.,Gözükara, Engin M.,(1997). Kit bağımlı beckman synchron cx3 analizörü için alternatif kreatinin çözeltisi.Turgut Özal Tıp Merkezi Dergisi, 4 (2).182-184 ss.en_US
dc.identifier.endpage186en_US
dc.identifier.issue2en_US
dc.identifier.startpage182en_US
dc.identifier.urihttp://www.totmdergisi.org/articles/1997/volume4/issue2/1997_4_2_11.pdf
dc.identifier.urihttps://hdl.handle.net/11616/2647
dc.identifier.volume4en_US
dc.language.isotren_US
dc.publisherİnönü Üniversitesi Tıp Fakültesi Dergisien_US
dc.relation.ispartofTurgut Özal Tıp Merkezi Dergisien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSynchron CX3en_US
dc.subjectKreatinin çözeltisien_US
dc.titleKit bağımlı beckman synchron cx3 analizörü için alternatif kreatinin çözeltisien_US
dc.title.alternativeAn alternative creatinine reagent for the reagent-dependent Beckman Synchron CX3 analyzeren_US
dc.typeArticleen_US

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
1997_4_2_11.pdf
Boyut:
279.33 KB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
Küçük Resim Yok
İsim:
license.txt
Boyut:
1.71 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: