A new approach to the determination of folic acid at trace levels: using a Fe(III)-folic acid complex to amplify analytical signal
dc.authorid | ULUSOY, HALIL IBRAHIM/0000-0002-8742-5145 | |
dc.authorid | erdogan, selim/0000-0002-9169-9771 | |
dc.authorid | ULUSOY, SONGUL/0000-0003-3640-5416 | |
dc.authorid | Acidereli, Hilal/0000-0003-4594-1712 | |
dc.authorwosid | ULUSOY, HALIL IBRAHIM/A-3777-2013 | |
dc.authorwosid | erdogan, selim/AAT-2487-2020 | |
dc.authorwosid | ULUSOY, SONGUL/AAA-9117-2021 | |
dc.contributor.author | Ulusoy, Songul | |
dc.contributor.author | Acidereli, Hilal | |
dc.contributor.author | Erdogan, Selim | |
dc.contributor.author | Ulusoy, Halil Ibrahim | |
dc.date.accessioned | 2024-08-04T20:41:47Z | |
dc.date.available | 2024-08-04T20:41:47Z | |
dc.date.issued | 2016 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description.abstract | A fast, efficient, cost-effective, and environmental-friendly analytical methodology was developed for preconcentration and determination of trace folic acid in food samples prior to high performance liquid chromatography with diode array detection (HPLC-DAD). The method is based on formation of stable complexes between folic acid and Fe(III) ions at pH 8.0. The formed complexes were extracted to a nonionic surfactant phase containing PONPE 7.5. The surfactant rich phase (SRP) was separated by decantation and diluted with 300 mu L of a mixture of 1 M HCl and methanol at a 1 : 1 ratio. The parameters and variables that affected the method were also investigated and optimized in detail. The limit of detection (LOD) of folic acid was 6.06 ng mL(-1), the linear range of quantitation for folic acid was 20-1200 ng mL(-1) and the correlation coefficients of the calibration curves were 0.9976. The average recoveries and relative standard deviations in the analysis of real samples were in the range of 95.1-105.1% and 1.73-5.25%, respectively. After validation of the method was carried out, the method was applied to the determination of folic acid in real samples, including baby foods, vegetables, cereals, and pharmaceutical samples. | en_US |
dc.description.sponsorship | Cumhuriyet University Scientic Research Projects Commission [ECZ-004] | en_US |
dc.description.sponsorship | This study has been supported by Cumhuriyet University Scientific Research Projects Commission as the research project with the ECZ-004 code. Authors gratefully thank Prof. Dr Sahin YILDIRIM for his useful comments and contributions to the preparation of the project text. | en_US |
dc.identifier.doi | 10.1039/c6ra05286j | |
dc.identifier.endpage | 40122 | en_US |
dc.identifier.issn | 2046-2069 | |
dc.identifier.issue | 46 | en_US |
dc.identifier.scopus | 2-s2.0-84971006876 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 40115 | en_US |
dc.identifier.uri | https://doi.org/10.1039/c6ra05286j | |
dc.identifier.uri | https://hdl.handle.net/11616/97348 | |
dc.identifier.volume | 6 | en_US |
dc.identifier.wos | WOS:000374974300070 | en_US |
dc.identifier.wosquality | Q2 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Royal Soc Chemistry | en_US |
dc.relation.ispartof | Rsc Advances | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cloud-Point Extraction | en_US |
dc.subject | Water-Soluble-Vitamins | en_US |
dc.subject | Spectrophotometric Method | en_US |
dc.subject | Food Samples | en_US |
dc.subject | Preconcentration | en_US |
dc.subject | Chromatography | en_US |
dc.subject | Separation | en_US |
dc.subject | Methotrexate | en_US |
dc.subject | Tablets | en_US |
dc.subject | Plasma | en_US |
dc.title | A new approach to the determination of folic acid at trace levels: using a Fe(III)-folic acid complex to amplify analytical signal | en_US |
dc.type | Article | en_US |