Immediate measurements of electric field strengths of electromagnetic field sources operating at very high frequencies on all floors of 15 faculties, 5 institutes, 2 colleges, cafeterias, research laboratories buildings located in the center campus of Inonu University were carried out in the frequency range of 100 kHz - 8 GHz. In this context, the electric field intensity values were measured by Wavecontrol SMP Meter device approximately at 35 thousand locations between October and December of 2017. With the results obtained, electromagnetic field pollution maps were drawn. In this study, the faculties which have relatively high electric field strength values wereincluded. We have not measured a value that is appropriate for all of the criteria we have made and that is accurate to the limit values compared to the current standards.