Evaluation of marginal and internal adaptation of hybrid and nanoceramic systems with microcomputed tomography: An in vitro study

dc.authoridAvcu, Guler Yildirim/0000-0002-8461-7774
dc.authoridKeleş, Ali/0000-0003-2835-767X
dc.authorwosidAvcu, Guler Yildirim/ABG-9821-2020
dc.authorwosidyildirim avcu, guler/K-2278-2017
dc.authorwosidKeleş, Ali/J-5897-2015
dc.contributor.authorYildirim, Guler
dc.contributor.authorUzun, Ismail H.
dc.contributor.authorKeles, Ali
dc.date.accessioned2024-08-04T20:42:54Z
dc.date.available2024-08-04T20:42:54Z
dc.date.issued2017
dc.departmentİnönü Üniversitesien_US
dc.description.abstractStatement of problem. The accuracy of recently introduced chairside computer-aided design and computer-aided manufacturing (CAD-CAM) blocks is not well established, and marginal integrity and internal adaptation are not known. Purpose. The purpose of this in vitro study was to evaluate the marginal and internal adaptation of hybrid and nanoceramics using microcomputed tomography (mu-CT). Material and methods. The marginal and internal adaptation of 3 polymer-infiltrated ceramic network (PICN) materials (Vita Enamic EVE]; Lava Ultimate [LU]; Vita Suprinity [VS]) were compared with lithium disilicate (IPS e.max.CAD, IPS). Ninety-six specimens (48 dies and 48 crowns) were prepared (n=12 each group) using a chairside CAD-CAM system. The restorations were scanned with mu-CT, with 160 measurements made for each crown, and used in 2-dimensional (2D) analysis. The marginal adaptation of marginal discrepancy (MD), absolute marginal discrepancy (AMD), internal adaptation of shoulder area (SA), axial space (AS), and occlusal space (OS) were compared using appropriate statistical analysis methods (alpha=.05). Cement volumes were compared using 3D analysis. Results. The IPS blocks showed higher MD (130 mu m), AMD (156 mu m), SA (111 mu m) (P<.05), AS (52 mu m), and OS (192 mu m) than the other blocks (P<.01). The adaptation values of VS were significantly lower than those of the IPS block (P<.05). The adaption values of the LU and VE blocks were significantly lower than those of others (P<.01) but were statistically similar to one another (P>.05). IPS had the largest cement space at 18 mm(3) (P<.01). Conclusions. The marginal and internal adaptation values were within a clinically acceptable range for all 3 hybrids and nanoceramics tested.en_US
dc.description.sponsorshipInonu University [2014/38]en_US
dc.description.sponsorshipSupported by Inonu University, Scientific Research Projects Unit (2014/38).en_US
dc.identifier.doi10.1016/j.prosdent.2016.11.005
dc.identifier.endpage207en_US
dc.identifier.issn0022-3913
dc.identifier.issn1097-6841
dc.identifier.issue2en_US
dc.identifier.pmid28089331en_US
dc.identifier.scopus2-s2.0-85009818960en_US
dc.identifier.scopusqualityQ1en_US
dc.identifier.startpage200en_US
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2016.11.005
dc.identifier.urihttps://hdl.handle.net/11616/97668
dc.identifier.volume118en_US
dc.identifier.wosWOS:000407873400013en_US
dc.identifier.wosqualityQ1en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherMosby-Elsevieren_US
dc.relation.ispartofJournal of Prosthetic Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFinish Line Curvatureen_US
dc.subjectDigital Impressionsen_US
dc.subjectCad/Cam Systemsen_US
dc.subjectCeramic Crownsen_US
dc.subjectFiten_US
dc.subjectRestorationsen_US
dc.subjectCopingsen_US
dc.subjectDiscrepanciesen_US
dc.subjectTechnologiesen_US
dc.subjectScanneren_US
dc.titleEvaluation of marginal and internal adaptation of hybrid and nanoceramic systems with microcomputed tomography: An in vitro studyen_US
dc.typeArticleen_US

Dosyalar