Effects of Different Positive End-Expiratory Pressure Values on Liver Function and Indocyanine Green Clearance Test in Liver Transplantation Donors: A Prospective, Randomized, Double-Blind Study
Küçük Resim Yok
Tarih
2015
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Elsevier Science Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
Introduction. The aim of this study was demonstrate the influence of different positive end-expiratory pressure (PEEP) values on blood flow of the liver by indocyanine green (ICG) clearance test in donor patients. Methods. ICG clearance tests were conducted concurrently using a noninvasive monitor that tracks the plasma disappearance rate of ICG (PDR-ICG%/min) and 15-minute retention rate after administration of ICG (ICG-R15%). This study was performed in 40 patients who underwent right hepatectomy. Results. The positive end-expiratory pressure (PEEP) was 0 cm H2O in the first (control) group (group K) and 10 mm Hg in the second study group (group P). ICG clearance test values before general anesthesia (T0), after induction of general anesthesia (T1), after transection (T2), 24 hours postoperative (T3), and 72 hours postoperative (T4) were recorded. Simultaneously, hemoglobin (Hgb), hematocrit (Hct), platelet count, plasma levels of prothrombin (PT), International Normalized Ratio (INR), total bilirubin, direct bilirubin, albumin, aspartate aminotransferase, and alanine aminotransferase values were analyzed. In terms of the plasma disappearance rate and retention rate of ICG 15 minutes after administration, significant difference was not observed between groups. PT and INR values were different within comparisons groups (P < .05). There were significant differences in Hgb and Hct values compared with the baseline values (T0) within group (T1, T2, T3, T4) measurements and between group comparisons at T0 and T4 (P < .05). Systemic arterial pressure, mean arterial pressure, and central venous pressure were significantly different between the groups (P <.05). Conclusions. Given the small magnitude and limited clinical significance of these changes, we conclude that PEEP values between 0 and 10 cm H2O have no effect on global liver function and liver-related liabilities tests in patients undergoing elective liver donor surgery.
Açıklama
13th Luso-Brazilian Transplantation Congress / 12th Portuguese Transplantation Congress / 1st Iberian Meeting of Transplantation -- OCT 09-11, 2014 -- Lisbon, PORTUGAL
Anahtar Kelimeler
Peep, Hemodynamics
Kaynak
Transplantation Proceedings
WoS Q Değeri
Q4
Scopus Q Değeri
Q3
Cilt
47
Sayı
4