Detection of rotor fault in three-phase induction motor in case of low-frequency load oscillation
Küçük Resim Yok
Tarih
2015
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Springer
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
This paper proposes a method for the separation of broken rotor bar failure and low-frequency load fluctuation in line-fed three-phase induction motor. In practice, the presence of load fluctuation at has the same effect on a stator current of induction motor as a broken rotor bar fault. In such cases, the detection of broken rotor bar failure becomes difficult. To discern rotor fault and load oscillations, the analytical signal angular fluctuation (ASAF) method, which is a combination of Hilbert transform and the space vector angular fluctuation method, is used. The presented experimental results prove that low-frequency load oscillation and rotor fault can reliably be discriminated using the ASAF signal spectrum.
Açıklama
Anahtar Kelimeler
ASAF method, Broken rotor bar, Fault diagnosis, Fault detection, Hilbert transform, Induction motor, Load torque oscillation
Kaynak
Electrical Engineering
WoS Q Değeri
Q3
Scopus Q Değeri
Q2
Cilt
97
Sayı
4