dc.departmentİnönü Üniversitesien_US
dc.description.abstractThis paper proposes a method for the separation of broken rotor bar failure and low-frequency load fluctuation in line-fed three-phase induction motor. In practice, the presence of load fluctuation at has the same effect on a stator current of induction motor as a broken rotor bar fault. In such cases, the detection of broken rotor bar failure becomes difficult. To discern rotor fault and load oscillations, the analytical signal angular fluctuation (ASAF) method, which is a combination of Hilbert transform and the space vector angular fluctuation method, is used. The presented experimental results prove that low-frequency load oscillation and rotor fault can reliably be discriminated using the ASAF signal spectrum.en_US
dc.description.sponsorshipScientific Research Unit (SRU), Inonu University [2013/47]en_US
dc.description.sponsorshipThe authors would like to acknowledge the financial support provided by the Scientific Research Unit (SRU), Inonu University, Project No. 2013/47.en_US
dc.identifier.doi10.1007/s00202-015-0342-5
dc.identifier.endpage345en_US
dc.identifier.issn0948-7921
dc.identifier.issn1432-0487
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-84942372911en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage337en_US
dc.identifier.urihttps://doi.org/10.1007/s00202-015-0342-5
dc.identifier.urihttps://hdl.handle.net/11616/96987
dc.identifier.volume97en_US
dc.identifier.wosWOS:000361539600008en_US
dc.identifier.wosqualityQ3en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.ispartofElectrical Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectASAF methoden_US
dc.subjectBroken rotor baren_US
dc.subjectFault diagnosisen_US
dc.subjectFault detectionen_US
dc.subjectHilbert transformen_US
dc.subjectInduction motoren_US
dc.subjectLoad torque oscillationen_US
dc.titleDetection of rotor fault in three-phase induction motor in case of low-frequency load oscillationen_US
dc.typeArticleen_US

Dosyalar