Detection of rotor fault in three-phase induction motor in case of low-frequency load oscillation
dc.authorid | Göktaş, Taner/0000-0002-8218-3239 | |
dc.authorid | Goktas, Taner/0000-0002-8218-3239 | |
dc.authorid | Arkan, Muslum/0000-0001-5313-2400 | |
dc.authorwosid | Göktaş, Taner/GXV-9179-2022 | |
dc.authorwosid | Goktas, Taner/ABG-9388-2020 | |
dc.authorwosid | Özgüven, ÖmerülFaruk/ABH-1035-2020 | |
dc.authorwosid | Arkan, Muslum/A-5114-2016 | |
dc.contributor.author | Goktas, Taner | |
dc.contributor.author | Arkan, Muslum | |
dc.contributor.author | Ozguven, Omer Faruk | |
dc.date.accessioned | 2024-08-04T20:41:12Z | |
dc.date.available | 2024-08-04T20:41:12Z | |
dc.date.issued | 2015 | |
dc.department | İnönü Üniversitesi | en_US |
dc.description.abstract | This paper proposes a method for the separation of broken rotor bar failure and low-frequency load fluctuation in line-fed three-phase induction motor. In practice, the presence of load fluctuation at has the same effect on a stator current of induction motor as a broken rotor bar fault. In such cases, the detection of broken rotor bar failure becomes difficult. To discern rotor fault and load oscillations, the analytical signal angular fluctuation (ASAF) method, which is a combination of Hilbert transform and the space vector angular fluctuation method, is used. The presented experimental results prove that low-frequency load oscillation and rotor fault can reliably be discriminated using the ASAF signal spectrum. | en_US |
dc.description.sponsorship | Scientific Research Unit (SRU), Inonu University [2013/47] | en_US |
dc.description.sponsorship | The authors would like to acknowledge the financial support provided by the Scientific Research Unit (SRU), Inonu University, Project No. 2013/47. | en_US |
dc.identifier.doi | 10.1007/s00202-015-0342-5 | |
dc.identifier.endpage | 345 | en_US |
dc.identifier.issn | 0948-7921 | |
dc.identifier.issn | 1432-0487 | |
dc.identifier.issue | 4 | en_US |
dc.identifier.scopus | 2-s2.0-84942372911 | en_US |
dc.identifier.scopusquality | Q2 | en_US |
dc.identifier.startpage | 337 | en_US |
dc.identifier.uri | https://doi.org/10.1007/s00202-015-0342-5 | |
dc.identifier.uri | https://hdl.handle.net/11616/96987 | |
dc.identifier.volume | 97 | en_US |
dc.identifier.wos | WOS:000361539600008 | en_US |
dc.identifier.wosquality | Q3 | en_US |
dc.indekslendigikaynak | Web of Science | en_US |
dc.indekslendigikaynak | Scopus | en_US |
dc.language.iso | en | en_US |
dc.publisher | Springer | en_US |
dc.relation.ispartof | Electrical Engineering | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | ASAF method | en_US |
dc.subject | Broken rotor bar | en_US |
dc.subject | Fault diagnosis | en_US |
dc.subject | Fault detection | en_US |
dc.subject | Hilbert transform | en_US |
dc.subject | Induction motor | en_US |
dc.subject | Load torque oscillation | en_US |
dc.title | Detection of rotor fault in three-phase induction motor in case of low-frequency load oscillation | en_US |
dc.type | Article | en_US |