Development of gallic acid sensors based on polyimide-modified platinum electrode
Küçük Resim Yok
Tarih
2019
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Taylor & Francis Inc
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
A series aromatic polyimide (PI) membranes in the form of permselective films was synthesised from different dianhydrides with two diamine monomers for gallic acid (GA) measurement. The obtained PI films were examined by Spectroscopic techniques, Scanning Electron Microscopy (SEM) and thermal analysis techniques and then used to fabricate the selective films on the modified electrode. Because of their excellent film properties, as the permselective polymeric membranes were used for determination of GA in the presence of various interferences and real sample. The PI-1-modified Pt electrode showed a very high R-value (0.9935) and reproducibility for GA determination, as well as high selectivity. [GRAPHICS]