Development of gallic acid sensors based on polyimide-modified platinum electrode

dc.authoridPASAHAN, Aziz/0000-0002-0657-3884
dc.authoridKoytepe, Suleyman/0000-0002-4788-278X
dc.authorwosidKöytepe, Süleyman/AAA-4168-2021
dc.authorwosidPAŞAHAN, Aziz/ABI-3519-2020
dc.authorwosidDURAN, SERAP TİTRETİR/AAF-7927-2020
dc.contributor.authorPasahan, Aziz
dc.contributor.authorAyhan, Nurcan
dc.contributor.authorOzcan, Imren
dc.contributor.authorDuran, Serap Titretir
dc.contributor.authorKoytepe, Suleyman
dc.date.accessioned2024-08-04T20:46:58Z
dc.date.available2024-08-04T20:46:58Z
dc.date.issued2019
dc.departmentİnönü Üniversitesien_US
dc.description.abstractA series aromatic polyimide (PI) membranes in the form of permselective films was synthesised from different dianhydrides with two diamine monomers for gallic acid (GA) measurement. The obtained PI films were examined by Spectroscopic techniques, Scanning Electron Microscopy (SEM) and thermal analysis techniques and then used to fabricate the selective films on the modified electrode. Because of their excellent film properties, as the permselective polymeric membranes were used for determination of GA in the presence of various interferences and real sample. The PI-1-modified Pt electrode showed a very high R-value (0.9935) and reproducibility for GA determination, as well as high selectivity. [GRAPHICS]en_US
dc.description.sponsorshipInonu University Scientific Research Projects Unit [BAP 2016/116]en_US
dc.description.sponsorshipThe authors thank the Inonu University Scientific Research Projects Unit for their financial support under the grant BAP 2016/116.en_US
dc.identifier.doi10.1080/03602559.2018.1542720
dc.identifier.endpage1139en_US
dc.identifier.issn2574-0881
dc.identifier.issn2574-089X
dc.identifier.issue10en_US
dc.identifier.scopus2-s2.0-85075806729en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.startpage1125en_US
dc.identifier.urihttps://doi.org/10.1080/03602559.2018.1542720
dc.identifier.urihttps://hdl.handle.net/11616/99079
dc.identifier.volume58en_US
dc.identifier.wosWOS:000476573100006en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.language.isoenen_US
dc.publisherTaylor & Francis Incen_US
dc.relation.ispartofPolymer-Plastics Technology and Materialsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPolyimidesen_US
dc.subjectmembranesen_US
dc.subjectsensorsen_US
dc.subjectgallic aciden_US
dc.titleDevelopment of gallic acid sensors based on polyimide-modified platinum electrodeen_US
dc.typeArticleen_US

Dosyalar