Evaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty

dc.contributor.authorKalcioglu, M. Tayyar
dc.contributor.authorUzun, Ismail Hakki
dc.contributor.authorYalcin, Muhammet
dc.contributor.authorMalkoc, Meral Arslan
dc.contributor.authorÖğreten, Ayse Tuba
dc.contributor.authorHanege, Fatih Mehmet
dc.date.accessioned2020-06-01T11:39:12Z
dc.date.available2020-06-01T11:39:12Z
dc.date.issued2015-01
dc.departmentİnönü Üniversitesien_US
dc.descriptionBALKAN MEDICAL JOURNAL Volume: 32 Issue: 1 Pages: 23-29en_US
dc.description.abstractBackground: Glass ionomer cements (GIC) have been widely used in dentistry for many years. In recent years, GIC have also been used for ossiculoplasty. The bond strength of GIC used in ossiculoplasty and the way they may change over the years in the cementation area are being questioned. The bonding strength of the substance may be of importance for long-term outcomes. Aims: The aim of this study was to investigate the bond strength of different GIC on ossicles. Study Design: In vitro study. Methods: Twenty ossicles were obtained from patients who had undergone ear surgery. All specimens were randomly divided into four subgroups. All specimens were inserted into a specially designed apparatus for shear bond strength (SBS) testing. The tested materials [Aqua Meron (AM), Aqua Cem (AC), Ketac Cem (KC), and Otomimix CPB (OH)] were prepared and applied according to the manufacturer's instructions. The SBS was tested using a universal testing machine at a crosshead speed of 0.5 mm/min. Results: The mean SBSs were found to be 13.28 MPa, 23.43 MPa, 8.51MPa, and 1.78 MPa for AM, AC, KC, and OH, respectively. AC had the highest SBS, which was statistically significantly different from that of KC and OH (p<0.05). Both AM and KC had higher SBS than OH (p<0.05). Conclusion: The results obtained in this study by investigating the bone-bonding strength of cements widely used in ossiculoplasty demonstrate that some of these substances have a greater ability to bond to ossicles compared to others. Further clinical investigations are needed to test different parameters.en_US
dc.identifier.citationKalcioglu, M. T., Uzun, I.H., Yalcin, M., Malkoc, M.A., Ogreten, A.T., Hanege, F.M. Evaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplasty. (2015). BALKAN MEDICAL JOURNAL.en_US
dc.identifier.doi10.5152/balkanmedj.2015.15829en_US
dc.identifier.endpage29en_US
dc.identifier.issn2146-3123
dc.identifier.issn2146-3131
dc.identifier.issue1en_US
dc.identifier.pmid25759768en_US
dc.identifier.scopus2-s2.0-84922838730en_US
dc.identifier.scopusqualityQ3en_US
dc.identifier.startpage23en_US
dc.identifier.trdizinid168037en_US
dc.identifier.urihttps://doi.org/10.5152/balkanmedj.2015.15829
dc.identifier.urihttps://hdl.handle.net/11616/15616
dc.identifier.urihttps://search.trdizin.gov.tr/yayin/detay/168037
dc.identifier.volume32en_US
dc.identifier.wosWOS:000351489300004en_US
dc.identifier.wosqualityQ4en_US
dc.indekslendigikaynakTR-Dizinen_US
dc.indekslendigikaynakWeb of Scienceen_US
dc.indekslendigikaynakScopusen_US
dc.indekslendigikaynakPubMeden_US
dc.language.isoenen_US
dc.publisherAVES,en_US
dc.relation.ispartofBalkan Medical Journalen_US
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectBone cementen_US
dc.subjectbond strengthen_US
dc.subjectossiculoplastyen_US
dc.subjectossiclesen_US
dc.titleEvaluation on Shear Bond Strength of Different Glass Ionomer and Hydroxy Apatite Cements Used in Ossiculoplastyen_US