Evaluation of trueness and precision of 3 face-scanning devices

dc.contributor.authorBor, Sabahattin
dc.contributor.authorOguz, Firat
dc.contributor.authorOzdemir, Deniz
dc.date.accessioned2026-04-04T13:35:16Z
dc.date.available2026-04-04T13:35:16Z
dc.date.issued2025
dc.departmentİnönü Üniversitesi
dc.description.abstractIntroduction: This study evaluated the trueness and precision of three 3-dimensional facial scanning devices- MetiSmile (MS), Revopoint Miraco Plus (RMP), and Qlone Dental application (QA) using an iPhone 15 Pro. Methods: Forty-seven participants were scanned using MS, RMP, and QA under standardized conditions. Comprehensive accuracy evaluations (trueness and precision) were conducted. Deviations were assessed through superimposition, and the root mean square (RMS) was used to quantify these deviations. The deviation analysis was performed using CloudCompare software (v2.13.2, www.cloudcompare.org). Results: Trueness analysis showed that MS and RMP produced comparable results with deviations below 0.5 mm, whereas QA exhibited significantly higher deviations (P = 0.003; mean RMS = 0.938 mm for full-head scans). Precision analysis revealed MS had the lowest mean RMS deviation (0.309 mm), indicating the highest consistency, followed by RMP (0.362 mm). QA demonstrated the least precision (mean RMS = 0.657 mm). Comparative analysis indicated MS and RMP scans were similar, whereas QA showed greater deviations. Conclusions: The MS and RMP devices exhibit high accuracy, making them suitable for orthodontic diagnostics and treatment planning. Although less accurate, the QA is also applicable for these purposes. (Am J Orthod Dentofacial Orthop 2025;168:358-66)
dc.identifier.doi10.1016/j.ajodo.2025.04.009
dc.identifier.issn0889-5406
dc.identifier.issn1097-6752
dc.identifier.issue3
dc.identifier.pmid40323245
dc.identifier.scopus2-s2.0-105004373617
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.ajodo.2025.04.009
dc.identifier.urihttps://hdl.handle.net/11616/109707
dc.identifier.volume168
dc.identifier.wosWOS:001562357100001
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.indekslendigikaynakPubMed
dc.language.isoen
dc.publisherMosby-Elsevier
dc.relation.ispartofAmerican Journal of Orthodontics and Dentofacial Orthopedics
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_WOS_20250329
dc.subjectAccuracy
dc.titleEvaluation of trueness and precision of 3 face-scanning devices
dc.typeArticle

Dosyalar