Fabrication of a Portable Magnetic Microcantilever Using Fe40Ni38Mo4B18 Amorphous Ribbon and Its Application as a Humidity Sensor by Coating with TiO2 Nanotubes

Küçük Resim Yok

Tarih

2024

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Mdpi

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Microcantilevers (MCs) are highly sensitive sensors capable of detecting mass changes on the surface at the nanogram and even picogram scale. In this study, microcantilevers were fabricated for the first time using the Sodick AP250L Wire electrical discharge machining (EDM) from amorphous 2826MB (Fe40Ni38Mo4B18) ferromagnetic ribbons. This method is advantageous because it allows for the simultaneous production of a large number of microcantilevers, with about 100 MCs being produced in a single manufacturing process. Additionally, a straightforward and cost-effective measurement system was developed to measure the resonance frequency and frequency shift of the MC entirely through magnetic means, a technique not previously reported in the literature. To evaluate the performance of the MC, we employed it as a humidity sensor. For the TiO2-NT-coated MC, a frequency shift of approximately 202 Hz was observed when the humidity level changed from 5% to 95% relative humidity (RH).

Açıklama

Anahtar Kelimeler

amorphous ferromagnetic ribbon, microcantilever, resonance frequency, humidity, TiO2

Kaynak

Magnetochemistry

WoS Q Değeri

Q2

Scopus Q Değeri

Q2

Cilt

10

Sayı

12